70mm2 95mm2 China Bare Aluminum Conductor AAC Power Cable With IEC DIN ASTM Standard
70mm2 95mm2 China Bare Aluminum Conductor AAC Power Cable With IEC DIN ASTM Standard
Unit Price: | 0.36~8 USD |
---|---|
Min. Order: | 1000 Meter |
Packaging: | The Package for AAC Bare Conductor as following: Export Wooden Drums or Steel Wooden Drums or Steel Drums. |
---|---|
Transportation: | Express,Ocean,Land,Air |
Supply Ability: | 10000 Kilometer/Kilometers per Month |
Port: | Qingdao Shanghai Ningbo Guangzhou |
Product Description
70mm2 95mm2 China Bare Aluminum Conductor AAC Power Cable With IEC DIN ASTM Standard
Products Description
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are
available for this purpose.
Advantage:
1. High Current Carrying Capacity.
2. Excellent resistance to corrosion.
3. Ideal for use in coastal area.
4. Suitable for low & medium voltage lines in urban area.
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are
available for this purpose.
Advantage:
1. High Current Carrying Capacity.
2. Excellent resistance to corrosion.
3. Ideal for use in coastal area.
4. Suitable for low & medium voltage lines in urban area.
Standard
ASTM B 231, BS 215, IEC 61089, DIN 48201, BS EN 50182
The technical data of AAC(All Aluminum Bare Conductor Cable) as below for reference,any customized is available.
Product parameters
IEC 61089 | ||||||||||||
Code Name | Nominal | No./Nominal diameter of wires | Approximate Overall Diameter | Approximate Weight | Nominal Breaking Load | Nominal DC Resistance at 20°C | ||||||
mm2 | No./mm | mm | kg/km | KN | ohm/km | |||||||
10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 | ||||||
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 | ||||||
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 | ||||||
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 | ||||||
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 | ||||||
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 | ||||||
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 | ||||||
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 | ||||||
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 | ||||||
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 | ||||||
315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 | ||||||
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 | ||||||
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 | ||||||
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 | ||||||
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 | ||||||
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 | ||||||
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 | ||||||
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 | ||||||
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 | ||||||
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 | ||||||
1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 | ||||||
1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 | ||||||
1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 | ||||||
1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
ASTM B231 | ||||||||||||||
Code Name | Total Area | Stranding and Wire Diameter | Overall Diameter | Liner Mass | Nominal Breaking Load | Max. D.C. Resistance at 20ºC | ||||||||
AWG or MCM | mm² | mm | mm | kg/km | daN | Ω/km | ||||||||
Peachbell | 6 | 13.29 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 | |||||||
Rose | 4 | 21.16 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 | |||||||
Iris | 2 | 33.61 | 7/2.474 | 7.42 | 93 | 597 | 0.8577 | |||||||
Pansy | 1 | 42.39 | 7/2.776 | 8.33 | 117 | 732 | 0.6801 | |||||||
Pappy | 1/0 | 53.48 | 7/3.119 | 9.36 | 147 | 873 | 0.539 | |||||||
Aster | 2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 1100 | 0.4276 | |||||||
Phlox | 3/0 | 85.03 | 7/3.932 | 11.8 | 234 | 1347 | 0.339 | |||||||
Oxlip | 4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 1698 | 0.2688 | |||||||
Valerian | 250 | 126.71 | 19/2.913 | 14.57 | 349 | 2062 | 0.2275 | |||||||
Sneezewort | 250 | 126.71 | 7/4.80 | 14.4 | 349 | 2007 | 0.2275 | |||||||
Laurei | 266.8 | 135.16 | 19/3.01 | 15.05 | 373 | 2200 | 0.2133 | |||||||
Dalsy | 266.8 | 135.16 | 7/4.96 | 14.9 | 373 | 2141 | 0.2133 | |||||||
Peany | 300 | 152 | 19/3.193 | 15.97 | 419 | 2403 | 0.1896 | |||||||
Tulip | 336.4 | 170.45 | 19/3.381 | 16.01 | 470 | 2695 | 0.1691 | |||||||
Daftodil | 350 | 177.35 | 19/3.447 | 17.24 | 489 | 2804 | 0.1625 | |||||||
Canna | 397.5 | 201.42 | 19/3.673 | 18.36 | 555 | 3184 | 0.1431 | |||||||
Goldentufl | 450 | 228 | 19/3.909 | 19.55 | 629 | 3499 | 0.1264 | |||||||
Syringa | 477 | 241.68 | 37/2.882 | 20.19 | 666 | 3849 | 0.1193 | |||||||
Cosmos | 477 | 241.68 | 19/4.023 | 20.12 | 666 | 3708 | 0.1193 | |||||||
Hyacinth | 500 | 253.35 | 37/2.951 | 20.65 | 698 | 4035 | 0.1138 | |||||||
Zinnia | 500 | 253.35 | 19/4.12 | 20.6 | 698 | 3888 | 0.1138 | |||||||
Dahlia | 556.5 | 282 | 19/4.346 | 21.73 | 777 | 4327 | 0.1022 | |||||||
Mistletoe | 556.5 | 282 | 37/3.114 | 21.79 | 777 | 4362 | 0.1022 | |||||||
Meadowsweet | 600 | 304 | 37/3.233 | 22.63 | 838 | 4703 | 0.0948 | |||||||
Orchid | 636 | 322.25 | 37/3.33 | 23.31 | 888 | 4985 | 0.0894 | |||||||
Heuchera | 650 | 329.35 | 37/3.366 | 23.56 | 908 | 5095 | 0.0875 | |||||||
Flag | 700 | 354.71 | 61/2.72 | 24.48 | 978 | 5146 | 0.0813 |
BS 215 Part 1 | ||||||||||||||
Code name | Nominal | No./Nominal diameter of wires | Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC | |||||||
mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | ||||||||
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 | |||||||
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 | |||||||
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 | |||||||
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 | |||||||
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 | |||||||
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 | |||||||
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 | |||||||
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 | |||||||
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 | |||||||
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 | |||||||
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 | |||||||
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 | |||||||
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 | |||||||
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 | |||||||
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 | |||||||
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 | |||||||
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 | |||||||
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 | |||||||
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 | |||||||
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 | |||||||
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 | |||||||
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 | |||||||
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 | |||||||
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 | |||||||
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 | |||||||
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 | |||||||
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 | |||||||
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 | |||||||
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 | |||||||
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
DIN 48201 Part 5 | ||||||||||||
Nominal Area | Calculated Area | Stranding and Wire Diameter | Overall Diameter | Weight | Calculated Breaking Load | Max.DC Resistance at 20° C | ||||||
mm2 | mm2 | No.xmm | mm | kg/km | daN | Ω/Km | ||||||
16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 | ||||||
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 | ||||||
35 | 34.36 | 7/2.50 | 7.5 | 94 | 585 | 0.8332 | ||||||
50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 | ||||||
55 | 48.35 | 19/1.80 | 9 | 133 | 860 | 0.595 | ||||||
70 | 65.81 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 | ||||||
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 | ||||||
120 | 116.99 | 19/2.80 | 14 | 322 | 1910 | 0.2459 | ||||||
150 | 147.11 | 37/2.25 | 15.8 | 406 | 2570 | 0.196 | ||||||
185 | 181.62 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 | ||||||
240 | 242.54 | 61/2.25 | 20.3 | 670 | 4015 | 0.1191 | ||||||
300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 | ||||||
400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.0722 | ||||||
500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.0578 | ||||||
625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 | ||||||
800 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 | ||||||
1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
RELATED PRODUCTS
Similar Products(Different structure; Different size)
AAC(All Aluminum Conductor)
AAAC(All Aluminum Alloy Conductor)
ACSR(Aluminun Conductor Steel Reinforced)
ACSR/AW ACSR/AS ACSR/AC
AACSR TACSR TACSR/AW
ACAR(Aluminum Conductor Aluminum Alloy Reinforced)
ACCC(Aluminum Composite Core Conductor)
Galvanized Steel Wire /Strand(GSW,SC/GZ)
Aluminum Clad Steel Wire(Alumoweld,ACS,SC/AC)
Aluminum Rod
AAAC(All Aluminum Alloy Conductor)
ACSR(Aluminun Conductor Steel Reinforced)
ACSR/AW ACSR/AS ACSR/AC
AACSR TACSR TACSR/AW
ACAR(Aluminum Conductor Aluminum Alloy Reinforced)
ACCC(Aluminum Composite Core Conductor)
Galvanized Steel Wire /Strand(GSW,SC/GZ)
Aluminum Clad Steel Wire(Alumoweld,ACS,SC/AC)
Aluminum Rod
COMPANY STRENGTH
COMPANY PROFILE
HENAN KINGYEAR GROUP was founded in 2006,located in the Gongyi industry area of Henan Province.Occupies more than 1200,000 square meters,more than 800 employees.Our company consists of 3 main subsidiaries,Business specialized in development,manufacture and distribution of aluminum and cable products.Mainly including aluminum plate,aluminum coil,bare aluminum conductor,aerial bundled cable,Low voltage and medium voltage power cable,Electrical wire,Control Cable,etc... CLICK MORE
PLANT AND OFFICE SHOWN:
3 workshops of All Aluminum Bare Conductor AAC conductor. 1 office building of international trade.
TESTING MACHINE SHOWN: All Aluminum Bare Conductor AAC conductor testing :
CERTIFICATE SHOWN:
ISO,CE,CCC,ROHS,UL,VDE of bare conductor AAC cable.
CUSTOMER
After more than 20 years of development, our customers have spread to more than 40 countries and regions around the world, And more than 50% are old customers.The power cable,control cable,ABC cable,bare conductor(AAC/AAAC/ACSR) are more favorited by them.We are proud of our good quality---KINGYEAR CABLE.
PACKAGE
PACKAGING FLOW of All Aluminum Bare Conductor AAC conductor as below,customized is accepted.
Some of our products packaging records shown:
They are about All Aluminum Bare Conductor AAC conductor and power cable.
FAQ
Q:I didn't find the all aluminum conductor aac conductor which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us,we will send you the free sample, but the freight charge should be paid.
Q:How to ensure quality ?
A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.
Product Categories : Bare Conductor > AAC(All Aluminum Conductor)
Premium Related Products
Other Products
Hot Products
Servo Feedback Motor Cable MOTORFLEX-X EMV 1/1 Triple Shielded Low Capacitance +80 C/+176 F 600 V PUR Flexible VFD Moto 4 core0.66 / 1.14KV Coal Cutter Semi-conducting Screened Monitoring Braided Flexible Cable
Elastomer (Rubber) Insulated CableKVV32 steel wire armored cable SWA control cable2/0 AWG green ground PVC stranded copper cableXLPE Cable 500mcm Copper Cables XHHW-2 Wire AWG2 Core 0.71mm Drop wire outdoor telephone cable factory3 Core AL XLPE Insulated 300mm 15kV 25kV Underground Cable4 sq mm Aluminum Core PVC Insulated Wire 16mm2 Single Core CableBC 2 x 20 Gauge 0.8mm Drop Wire Outdoor Telephone Cable6.35/11kV Screened ABC Aerial Bundled CablesAluminum Conductor Aerial Concentric Cable KS 1022:2015 standard2/0 SGT SAE J1127 105 C PVC Insulation Automotive battery cable
Automotive Battery Cable
SGT Automotive Battery CableBare ACSR Cable Aluminum Conductor 120mm2AAsXSn CCX-AL3 WK 12/20 (24) kV Cable XLPE Insulated Medium Voltage Overhead LineSingle core PVC 6181XY Cable Double Insulated Surface WireDouble insulated cable 6181Y for building wiring