Find SER Wire, Service Cable , Service Entrance Wire on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
SPT lamp wire SPT Cable (SPT-1, SPT-2 and SPT-3 Lamp Cord)
Home > Products > TW,THW,UD,TTU,SER Wire > SPT lamp wire SPT Cable (SPT-1, SPT-2 and SPT-3 Lamp Cord)

SPT lamp wire SPT Cable (SPT-1, SPT-2 and SPT-3 Lamp Cord)

Product Description

wire SJTW SJT/SJTW/SJTOW PVC cable wire

600v  wire-NMD 90 Construction wire PVC Insulated jacket

 

NMD 90 Construction wire
ISO9001:2008 STANDARD

NMD 90 Construction wire Flat wire twin and earth

Specifications

SJT/SJTW/SJTOW PVC cable wire(UL Certificated) 
Rated Voltage: 300V 
Temperature Range 60~105oC 
Conductor: Copper Twiste wire

SJT/SJTW/SJTOW PVC cable wire(UL Certificated)

1) Rated Voltage: 300V 
2) Temperature Range 60~105oC
3) Conductor: Copper Twisted Wire  
4) Any special request can be produced specially according to client's special request.


Specification:

 

 

Cable Type

AWG

Conductor

Insulation thickness

Jacket

Amp Rating
(A)

No. Of Conductor

Sectional Area
(mm2)

Construction
(No./mm)

Thickness
(mm)

Diameter
(mm)

Thickness
(mm)

Diameter
(mm)

SJT/SJTW/SJTOW

10

2

5.26

72/0.31

1.14

5.4

1.52

14.1

30

10

3

5.26

72/0.31

1.14

5.4

1.52

14.8

30

12

2

3.31

47/0.31

0.76

4.0

1.14

10.5

20

12

3

3.31

47/0.31

0.76

4.0

1.14

11.0

20

14

2

2.08

41/0.254

0.76

3.5

0.76

8.70

15

14

3

2.08

41/0.254

0.76

3.5

0.76

9.30

15

16

2

1.31

50/0.18

0.76

3.1

0.76

7.95

13

16

3

1.31

50/0.18

0.76

3.1

0.76

8.40

13

18

2

0.82

32/0.18

0.76

2.8

0.76

7.35

10

18

3

0.82

32/0.18

0.76

2.8

0.76

7.80

10

 

 

APPLICATIONS of  NMD 90 Construction wire Flat wire twin and earth
NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts.

NM-B (nonmetallic-sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code 1 . 
CONSTRUCTION:
NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a ground wire. Copper conductors are annealed (soft) copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Designed for Easier Pulling, Resulting in Easier installation.

 

Specifications of  NMD 90 Construction wire Flat wire twin and earth

Type NM-B Building Cable 
1.Conductor: Cooper 
2.Insulator:PVC with Nylon 
3.Ground:Soft bare copper 
4.Sheath:PVC

Application

Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90ºC, its ampacity is limited to 60ºC according to the NEC. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness.

Construction
  • Conductor : Solid #14 - 10 AWG annealed soft bare copper or Stranded #8 AWG and larger annealed soft bare copper .
  • Insulation : Color coded polyvinyl chloride (PVC) compound with a nylon jacket meeting the required thickness of Type THHN. Conductor insulation is rated 90ºC.
  • Ground : soft bare copper
  • Sheath :color-coded PVC
Features
  • NM-B is designed for Easier Pulling, Resulting in Easier installation.
  • The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow – 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG.
  • LEAD FREE and RoHS compliant

Technical

  • Maximum operation voltage: 600 V 
  • Maximum temperature: 90°C
Parameter
Conductor Size AWG
No. of
Conductors
PVC Insulation
Thickness
Ground Wire Size AWG Nylon
Thickness
Approximate cable dimensions Approximate
Cable Weight

Ampacity* Amps
mm mm mm kg/km
Two conductors
14 (1) 2 0.38 14 (1) 0.10 4.0 x 9.1 85 15
12 (1) 2 0.38 12 (1) 0.10 4.3 x 10.2 122 20
10 (1)

2 0.51 10 (1) 0.10 5.3 x 12.4 185 30
8 (7)

2 0.76 10 (1) 0.13 6.9 x 15.0 277 40
6 (7) 2 0.76 10 (1) 0.13 8.1 x 17.3 379 50
Three Conductors
14 (1) 3 0.38 14 (1) 0.10 7.9 110 15
12 (1) 3 0.38 12 (1) 0.10 8.6 159 20
10 (1) 3 0.51 10 (1) 0.10 10.9 243 30
8 (7) 3 0.76 10 (1) 0.13 14.2 378 40
6 (7) 3 0.76 10 (1) 0.13 16.0 531 55
4 (7) 3 1.02 8 (7) 0.15 21.6 882 70
2 (7) 3 1.02 6 (7) 0.15 24.9 1274 95
Four conductors
14 (1) 2/2 ** 0.38 14 (1) 0.10 8.9 135 15
14 (1) 4 *** 0.38 14 (1) 0.10 8.9 135 15
12 (1) 2/2 * 0.38 12 (1) 0.10 9.7 196 20
12 (1) 4 *** 0.38 12 (1) 0.10 9.7 196 20


Using features of insulated cable:
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

Model: insulated flat cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable

 

1)We are not trading company, we’re factory and welcome to visit

2)Reasonable price, good quality and fast delivery

3)We have ISO9001:2000 and QS9000

4)Samples orders and OEM is accepted

5)Free to contact with us

 

Product Details:

 

 

 

Our Advantages

1)Good quality. All of the wire and cable have been approved by all kinds of international approval. Ect.:UL/CUL   VDE   CSA

2)We got ISO9001:2000 quality management system certificate

3)We have international standards of quality inspection system

4)Experienced technical team

5)We’d engaged in manufacturing wire and cable for about 20 years

6)We have many advanced equments

7)We have a best services team and will give you the best services

8)If you would like to visit our factory, we will pick you up from anywhere in Guangzhou and book the hotel for you.

 

Shipments:

As FOB price terms we deal, you can choose any shipping company you like, and we assure you we will work with them happily. And, if you are not good at finding shipping company, we can introduce the best we have worked with to you.

 

Package:

Normally, the wire and cable will be packed by carton ot plactic spools. But, if you have any other requirements of package, we will try our best to satisfy you.

 

Contacts:

If you have any questions please feel free to contact with us:

Wendy

Tel: 0086-13526646653

       0086-371-68822533

Contact us if you need more details on SJT/SJTW/SJTOW PVC Cable Wire. We are ready to answer your questions on packaging, logistics, certification or any other aspects about SJT/SJTW/SJTOW PVC Cable Wire、SJT/SJTW/SJTOW PVC Cable Wire. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : TW,THW,UD,TTU,SER Wire